E2638-O2

Oxygen Detector

Features
  • Electrochemical sensor
  • Range 0...25 %vol O2
  • Resolution 0,01 %vol O2
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Oxygen detector-transmitter E2638-O2 is a member of PluraSens® family of multifunctional measurement instruments.

The instrument may be used to prevent critical decrease of O2 concentration as well as to control the absence of the oxygen in gas mixtures.

The instrument utilises a fully calibrated and temperature compensated gas sensor with excellent repeatability, stability and long lifetime. 

Two relays with closing contact (optional) may be used for remote signalling or concentration control. Two alarm set-points are user settable.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical data
Calibration oxygen O2
Sensor type electrochemical
Sampling method diffusion
Detection range 0...25 %vol O2
Resolution 0,01 %vol O2
Sensor lifetime > 2 years
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays (option) 2 × SPST relays (closing contact),
Default alarm set-points 19,5 / 18,0 %vol O2
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H90 × W145 × D55 mm
Operating conditions -30...+50 °C, 15...90 %RH

Similar Products


Gasman - Personal single gas detector
Gasman - Personal single gas detector
  • Available for flammable gas, oxygen and toxic gases
  • Rechargeable versions for all gas types
  • Non rechargeable for oxygen and toxic gases
  • Loud 95dBA audible alarm

Tetra - Personal multigas monitor
Tetra - Personal multigas monitor
  • Battery non- or rechargeable options
  • Graphic LCD for clear view
  • Single button operation
  • Loud 94dBA audible alarm
  • Shock and vibration resistant, IP 65

TXgard+ - Toxic and oxygen gas detector
TXgard+ - Toxic and oxygen gas detector
  • Calibration can be performed locally without the need for hot work permits
  • Local display and magnetic key enable calibration without opening the junction box
  • 4...20mA signal is provided
  • Optional alarm and fault relays are available

TXgard-IS+ - Toxic and oxygen gas detector
TXgard-IS+ - Toxic and oxygen gas detector
  • Wide choice of sensors available
  • Local calibration option
  • 2-wire 4-20mA
  • Operating range: -20...+55 °C, 15...90% RH
  • ABS plastic housing, IP65