E2608-NO2

Nitrogen Dioxide Detector

Features
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...200 ppm NO2
  • Resolution 0,1 ppm or 1 ppm NO2
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Nitrogen dioxide detector-transmitter E2608-NO2 is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include underground parkings, boiler houses, kitchens, and other confined spaces, where potentially toxic concentration of nitrogen dioxide can accumulate.

The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.

Two relays with closing contact may be used for remote signalling or ventilation control. Two alarm set-points are user settable.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical data
Calibration nitrogen dioxide NO2
Sensor type electrochemical
Sampling method diffusion
Detection range 0...20 ppm NO2
0...200 ppm NO2
Resolution 0,1 ppm NO2 for 20 ppm range
1 ppm NO2 for 200 ppm range
Sensor lifetime > 2 years
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Default alarm set-points 3 ppm / 6 ppm NO2
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H85 × W82 × D55 mm
Operating conditions -20...+50 °C, 15...90 %RH

Similar Products


TXgard+ - Toxic and oxygen gas detector
TXgard+ - Toxic and oxygen gas detector
  • Calibration can be performed locally without the need for hot work permits
  • Local display and magnetic key enable calibration without opening the junction box
  • 4...20mA signal is provided
  • Optional alarm and fault relays are available

TXgard-IS+ - Toxic and oxygen gas detector
TXgard-IS+ - Toxic and oxygen gas detector
  • Wide choice of sensors available
  • Local calibration option
  • 2-wire 4-20mA
  • Operating range: -20...+55 °C, 15...90% RH
  • ABS plastic housing, IP65

Xsafe - Gas detector for non-hazardous areas
Xsafe - Gas detector for non-hazardous areas
  • Aluminium junction box
  • Working range: -40...+80°C, 0-99% RH
  • 3-wire 4-20 mA
  • IP65
  • Deploy in non-hazardous environment

E2618-NO2 - Nitrogen Dioxide Transmitter
E2618-NO2 - Nitrogen Dioxide Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...200 ppm NO2
  • Resolution 0,1 ppm or 1 ppm NO2
  • 2 × 4-20 mA or 0-10 V, RS485