Features Delivers rapid, fail-safe detection Fixed or remote display 4-20 mA, RS485, HART protocol Operating range -40...+75 °C, 0...100% RH Stainless steel IP66 enclosure Description - Add To Inquiry Documents TechnicalDatasheet UserManual
Flamgard - Flammable gas detector Calibration can be performed locally Local display and magnetic key enable calibration 4-20 mA Optional alarm and fault relays are available
Xgard - Flammable, toxic or oxygen gas detector Aluminium, stainless steel or glass-reinforced nylon body Operating range: -40...+80°C, 0-99% RH (non-condensing) 2- wire 4-20mA or 3- wire mV bridge IP54 to IP65 Deploy in hazardous environment certified
TXgard+ - Toxic and oxygen gas detector Calibration can be performed locally without the need for hot work permits Local display and magnetic key enable calibration without opening the junction box 4...20mA signal is provided Optional alarm and fault relays are available
E2610-LEL - Combustible Gas Detector Stable long-life metal-oxide sensor Range 0...100% LEL Two SPDT relays UART digital interface
E2608-LEL - Combustible Gas Detector Stable long-life metal-oxide / pellistor sensor Range 0...100% LEL Resolution 0,1 / 1 % LEL Two SPST relays 2 × 4-20 mA or 0-10 V, RS485
Xsafe - Gas detector for non-hazardous areas Aluminium junction box Working range: -40...+80°C, 0-99% RH 3-wire 4-20 mA IP65 Deploy in non-hazardous environment
E2618-LEL - Combustible Gas Transmitter Stable long-life metal-oxide / pellistor gas sensor Range 0...100% LEL Resolution 0,1 / 1 % LEL Wall mount or duct mount version Attached or remote sensor 2 × 4-20 mA or 0-10 V, RS485
E2630-LEL - Combustible Gas Detector Stable long-life metal-oxide sensor Range 0...100% LEL Two SPDT relays UART digital interface
E2638-LEL - Combustible Gas Detector Stable long-life metal-oxide / pellistor sensor Range 0...100% LEL Resolution 0,1 / 1 % LEL Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2611-LEL - Combustible Gases Detector Stable long-life metal-oxide sensor Range 0...100% LEL Resolution 0,1% LEL Two SPST relays 2 × 4-20 mA or 0-10 V, RS485
E2648-LEL - Combustible Gas Detector Stable long-life metal-oxide / pellistor sensor Range 0...100% LEL Resolution 0,1 / 1 % LEL Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2615-LEL - Combustible Gas Transmitter High long-term stability User selectable output 4-20 mA / 0-10 V Range of compact wall mount enclosures Low cost for volume HVAC applications
E2670-LEL - Flameproof Combustible Gas Detector Suitable for ATEX Zones 2 and 22 Stable long-life metal-oxide / pellistor sensor Range 0...100% LEL Resolution 0,1 / 1 % LEL Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2660-CO-LEL - Combustible Gases Transmitter Simultaneous CO and combustible gases monitoring RS485 Modbus RTU digital interface Two analog outputs 4-20 mA / 0-10 V Easy-to-install IP65 protected enclosure Attached or remote sensor Two SPST relays option Acoustic alarm option