E2611-VOC

Solvent Vapor Detector

Features
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Solvent vapor detector E2611-VOC is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include storages, painting chambers and other confined spaces, where toxic or potentially explosive concentration of volatile organic compounds can accumulate.

The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime.

According to user's preferences the detector can be ordered for either fire prevention, (range 0...100% LEL) or for toxicity prevention (range from 0...1000 ppm).

Two relays with closing contact may be used for remote signalling or ventilation control. Two alarm set-points are user settable. Internal buzzer gives sound alarms.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical data
Detected vapors acetone, ethanol, toluene, xylene etc
Default calibration toluene
Sensor type metal-oxide semiconductor
Sampling method diffusion
Detection range 0...100% LEL (flammable range)
0...1000 ppm (toxic range)
Resolution 0,1% LEL for LEL range
1 ppm for ppm range
Sensor lifetime > 5 years
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Alarms buzzer 85 dB
Default alarm set-points 20% LEL / 50% LEL
100 ppm / 300 ppm
Enclosure light-grey ABS plastic with ventilation slots, IP20
Dimensions H85 × W85 × D37 mm
Operating conditions -30...+70 °C, < 95 %RH