T3311

Relative humidity, temperature and dew point transmitter

Features
  • Temperature sensor: RTD Pt1000-3850ppm/°C
  • Measuring range: 0...100 %RH, -30...+80 °C
  • Accuracy: ±0.4°C
  • RS232 serial output
Description

Programmable temperature and humidity transmitter is equipped with temperature and relative humidity sensors. Measured values are also converted to other humidity interpretation - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy. Degrees Celsius and Fahrenheit are user selectable. 

Large dual line LCD for simultaneous display of T+RH or other humidity interpretation is an advantage. Display is possible to switch off. 

State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitters are designed for use in non-aggressive environment.


Technical data
Measured Value relative rumidity, temperature
Measuring range 0...100 %RH, -30...+80 °C
Temperature units Celsius, Fahrenheit
Temperature operating range -30...+80°C with electronics (if over 70°C, turn off LCD)
Communication protocol ModBus RTU and Advantech ADAM compatible protocol

Similar Products


E2007-HF - Heat flux transmitter
E2007-HF - Heat flux transmitter
  • Measurements from 2 to 2000 W/m2
  • Excellent repeatability and stability
  • Fully calibrated and temperature compensated
  • RS485 Modbus RTU interface
  • 0-10 V or 4-20 mA analog output options
  • Ideal for building climate control

E2227 - Interior humidity & temperature transmitter
E2227 - Interior humidity & temperature transmitter
  • Digital sensors with excellent repeatability and stability
  • Fully calibrated and temperature compensated
  • RS485 Modbus RTU interface
  • Two configurable 0-10 V / 4-20 mA outputs

P8610 - Industrial Ethernet Thermometer
P8610 - Industrial Ethernet Thermometer
  • Celsius- and Fahrenheit degrees supported
  • http, smtp, snmp, SOAP, telnet, www pages, Modbus TCP ..
  • Alarm functions: e-mail, traps, syslog, www pages
  • Long term stability of temperature

T4511 - Intelligent temperature transducer
T4511 - Intelligent temperature transducer
  • Measuring range: -200 to +600°C
  • Accuracy of the input without probes: ±0.2°C
  • Protection: IP20 electronics
  • LAN connection: RJ-45 connector
  • Power: 9-30Vdc, maximum consumption 200mA
  • Power connector: co-axial, diameter 5 x 2.1 mm

T3110 - Humidity and temperature transmitter
T3110 - Humidity and temperature transmitter
  • Accuracy of relative humidity measurement: ±2.5% relative humidity from 5 to 95% at 23 °C
  • Accuracy of temperature output: ±0.4 °C from -30 to +100 °C
  • Accuracy of dew point temperature output: ±0.5 °C from 30 to 95 %RH

T3111 - Programmable humidity, temperature and dew point transmitter
T3111 - Programmable humidity, temperature and dew point transmitter
  • Accuracy of relative humidity measurement: ±2.5% relative humidity from 5 to 95% at 23°C
  • Accuracy of temperature output: ±0.4°C from -30 to +100°C
  • Accuracy of dew point temperature output: ±0.5°C from 30 to 95% RH

T3117 - Programmable humidity, temperature and dew point transmitter
T3117 - Programmable humidity, temperature and dew point transmitter
  • Air relative humidity range: 0 to 100 %RH
  • Accuracy of temperature output: ±0.4 °C from -30 to +100 °C
  • Range of humidity sensor temperature compensation: -30 to +125 °C
  • Power: 9-30 Vdc

T02xx - Programmable humidity, temperature and dew point transmitters
T02xx - Programmable humidity, temperature and dew point transmitters
  • With 0-10 V output
  • Dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Easy programming, adjustment, calibration

T4111 - Programmable temperature transmitter
T4111 - Programmable temperature transmitter
  • Temperature operating range: -30...+80°C
  • Current output - two-wire connection: 4...20 mA
  • User adjustable from the PC
  • Protection class: IP65
  • Power: 9...30Vdc

T3411 - Relative humidity, temperature and dew point transmitter
T3411 - Relative humidity, temperature and dew point transmitter
  • Temperature sensor RTD Pt1000-3850ppm/°C
  • Measuring range 0...100 %RH, -30...+80 °C
  • Accuracy ±2.5 %RH from 5..95% at 23 °C
  • Range of temperature compensation of the humidity sensor -30...+80 °C

T3413D - Relative humidity, temperature and dew point transmitter
T3413D - Relative humidity, temperature and dew point transmitter
  • Temperature sensor RTD Pt1000-3850ppm/°C
  • Measuring temperature range -30 to +125 °C
  • Measuring air relative humidity range 0..100%
  • Accuracy ±2.5 %RH from 5..95% at 23 °C

T7510 - Temperature humidity transmitter with Ethernet interface
T7510 - Temperature humidity transmitter with Ethernet interface
  • http, smtp, snmp, telnet, www pages, Modbus TCP
  • Alarm functions: e-mail, traps, syslog, www pages
  • Online dew point temperature, absolute humidity, specific humidity, mixing ratio
  • Long term stability of temperature, humidity, pressure

P0120 - Temperature sensors and transducers
P0120 - Temperature sensors and transducers
  • Temperature measuring and operating range: -30...+80°C
  • Accuracy: ±0.4°C
  • Applied sensor: Pt100, Pt1000/3850ppm
  • Protection class: IP65
  • Power: 9 to 30 V DC (typically 24V)

T4311 - Temperature transducer
T4311 - Temperature transducer
  • Temperature input: Pt1000 - 3850ppm/°C
  • Measuring temperature range: -200...+600°C
  • Accuracy of the input without probes: ±0.2°C
  • Operating temperature range: -30 to +70°C
  • Communication protocol: ModBus and Advantech ADAM compatible protocol

T4411 - Temperature transducer
T4411 - Temperature transducer
  • Temperature input: Pt1000 - 3850ppm/°C
  • Measuring temperature range: -200...+600°C
  • Operating temperature range: -30...+70°C,
  • Communication protocol: ModBus and Advantech ADAM compatible protocol

COT212 - CO2 and temperature transmitter
COT212 - CO2 and temperature transmitter
  • Range 0...5000 ppm CO2
  • Two-lines 10-digits LCD display
  • Attached sensors 0...+50 °C
  • Remote probe 20...+80 °C
  • 0-5/10 V or 0/4-20 mA outputs
  • Software or DIP switch configuration

CTV110 - Air velocity and temperature transmitter
CTV110 - Air velocity and temperature transmitter
  • Air velocity 0...30 m/s
  • Temperature 0...+50 °C
  • 10-digits LCD display
  • Wall and duct mount versions
  • 0-10 V or 4-20 mA output
  • Software or DIP switch configuration

P86x1 - Ethernet thermo-hygrometer
P86x1 - Ethernet thermo-hygrometer
  • Temperature and relative humidity
  • http, smtp, snmp, SOAP, telnet, www pages, Modbus TCP ..
  • Alarm functions: e-mail, traps, syslog, www pages
  • Up to 4 external temperature probes
  • Long term stability of temperature

T6640 - Remote thermo-hygro-CO2-meter with Ethernet interface + PoE
T6640 - Remote thermo-hygro-CO2-meter with Ethernet interface + PoE
  • Measurement of temperature, humidity and CO2
  • Temperature measuring range -30...+80 °C
  • Humidity measuring range 5...95 %RH
  • CO2 range 0...2000 ppm
  • LCD display
  • Easy wireless communication
  • PoE feature

HF4 - Humidity & temperature transmitter
HF4 - Humidity & temperature transmitter
  • Relative humidity, temperature measurementand dew point calculation
  • Outstanding accuracy and repeatability
  • Hygromer® IN-1 humidity sensor
  • Auto-diagnostics and automatic correction
  • Selectable and scalable analog outputs
  • Various digital outputs