E2648-SO2

Sulfur Dioxide Detector

Features
  • Stable long-life electrochemical sensor
  • Range 0...50 or 0...2000 ppm SO2
  • Resolution 0,1 ppm or 1 ppm SO2
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Sulfur dioxide detector-transmitter E2648-SO2 is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include wine-making, food and beverage industry, paper mills, wastewater treatment stations, laboratories and other areas, where potentially toxic concentration of sulfur dioxide can accumulate.

The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.. 

Two relays with closing contact (optional) may be used for remote signalling or concentration control. Two alarm set-points are user settable.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical data
Calibration sulfur dioxide SO2
Sensor type electrochemical
Sampling method diffusion
Detection range 0...50 ppm SO2
0...2000 ppm SO2
Resolution 0,1 ppm SO2 for 50 ppm range
1 ppm SO2 for 2000 ppm range
Sensor lifetime > 2 years
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays (option) 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Enclosure die-cast aluminium, wall mount, IP66
Dimensions H120 × W125 × D57 mm
Operating conditions -30...+50 °C, 15...90 %RH

Similar Products


E2648-C2H4 - Ethylene Detector
E2648-C2H4 - Ethylene Detector
  • Humidity compensated electrochemical sensor
  • Range 0...10 / 0...200 / 0...1500 ppm C2H4
  • Resolution 0,1 / 1 / 1 ppm C2H4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-CH4 - Methane Detector
E2648-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-CL2 - Chlorine Detector
E2648-CL2 - Chlorine Detector
  • Stable long-life electochemical sensor
  • Range 0...10 ppm Cl2
  • Resoluton 0,1 ppm Cl2
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-CO - Carbon Monoxide Detector
E2648-CO - Carbon Monoxide Detector
  • Stable long-life electrochemical sensor
  • Range 0...300 or 0...1000 ppm CO
  • Resolution 1 ppm CO
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-ETO - Ethylene Oxide Detector
E2648-ETO - Ethylene Oxide Detector
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...100 ppm C2H4O
  • Resolution 0,1 ppm or 1 ppm C2H4O
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-H2S - Hydrogen Sulfide Detector
E2648-H2S - Hydrogen Sulfide Detector
  • Stable long-life electrochemical sensor
  • Range 0...100 or 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-HFC - Refrigerant Detector
E2648-HFC - Refrigerant Detector
  • Stable long-life metal-oxide sensor
  • Ranges 0...1000 / 0...2500 ppm halocarbon gas
  • Resolution 1 ppm halocarbon gas
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-LEL - Combustible Gas Detector
E2648-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-NH3-E - Ammonia Detector
E2648-NH3-E - Ammonia Detector
  • Stable long-life electrochemical sensor
  • Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
  • Resolution 1 ppm NH3
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-NO - Nitric Oxide Detector
E2648-NO - Nitric Oxide Detector
  • Stable long-life electrochemical sensor
  • Detection range 0...250 ppm NO
  • Resolution 1 ppm NO
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-NO2 - Nitrogen Dioxide Detector
E2648-NO2 - Nitrogen Dioxide Detector
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...200 ppm NO2
  • Resolution 0,1 ppm or 1 ppm NO2
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-O3 - Ozone Detector
E2648-O3 - Ozone Detector
  • Stable long-life electrochemical sensor
  • Range 0...5 ppm or 0...1 ppm O3
  • Resolution 0,01 ppm O3
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-PID - Solvent Vapors Detector
E2648-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-VOC - Solvent Vapors Detector
E2648-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-CO2 - Carbon Dioxide Detector
E2648-CO2 - Carbon Dioxide Detector
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range 0...10 000 ppm / 40 000 ppm / 5 %vol CO2
  • Resolution 1 ppm / 10 ppm / 0.01 %vol CO2
  • Two SPST relays (option)
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-O2 - Oxygen Detector
E2648-O2 - Oxygen Detector
  • Easy to install robust enclosure
  • Range 0...25 %vol O2
  • Two analog outputs settable to 4-20 mA or 0-10 V
  • RS485 Modbus RTU digital interface
  • Relay option
  • Remote probe option

E2648-NH3-P - Ammonia Detector
E2648-NH3-P - Ammonia Detector
  • Stable long-life pellistor sensor
  • Range 0...15% vol. (0…100% LEL)
  • Resolution 0.1% vol. or 1% LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485
  • Attached or remote sensor
  • Industrial IP66 wall mount housing