E2630-VOC

Solvent Vapor Detector

Features
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface
Description

Solvent vapor detector E2630-VOC is an easy-to-use instrument intended for solvent storages, painting chambers and other confined spaces, where toxic or potentially explosive concentration of volatile organic compounds can accumulate.

The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime.

According to user's preferences the detector can be ordered for either fire prevention (range 0...100% LEL) or for toxicity prevention (range 0...500 ppm).

Two relays with switch-over contact may be used for remote signalling or ventilation control. Flashing LED and internal buzzer give visual and sound alarms.


Technical data
Detected vapours acetone, ethanol, toluene, xylene etc
Default calibration toluene
Sensor type metal-oxide semiconductor
Sampling method diffusion
Detection range 0...100% LEL
0...500 ppm
Resolution 0,1% LEL for LEL range
1 ppm for ppm range
Sensor lifetime > 5 years
Power supply 24 VDC/AC ±20% (default)
or 230 VAC (optional)
Digital interface UART
Output relays 2 x SPDT relays (switch-over contact)
250 VAC / 30 VDC, 5 A max
Alarms blinking LED, buzzer 85 dB
Default alarm set-points 10% LEL / 25% LEL
100 ppm / 300 ppm
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H90 × W145 × D55 mm
Operating conditions -40…+70 °C, <95 %RH (non-condensing)