E2618-O3

Ozone Transmitter

Features
  • Stable long-life electrochemical sensor
  • Range 0...5 ppm or 0...1 ppm O3
  • Resolution 0,01 ppm O3
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Ozone transmitter E2618-O3 is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include swimming pools and spas, food factories, places where disinfection or bleaching is performed, and other confined spaces, where potentially toxic concentration of ozone  can accumulate.

The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the transmitter to safety or building automation systems.


Technical data
Calibration ozone O3
Sensor type electrochemical
Sampling method diffusion
Detection range 0...5 ppm,
0...1 ppm
Resolution 0,01 ppm
Repeatability < 2 % of signal
Sensor lifetime > 2 years (0...5 ppm)
> 18 months (0...1 ppm)
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -40...+50 °C (0...5 ppm),
-20...+40 °C (0...1 ppm),
15...90 %RH

Similar Products


Clip - Personal single gas detector
Clip - Personal single gas detector
  • Ensures worker safety
  • Short training time
  • No need for service or maintenance
  • Adjustable alarm levels
  • Real time gas reading or life left indication
  • Self test and test due indication

Gasman - Personal single gas detector
Gasman - Personal single gas detector
  • Available for flammable gas, oxygen and toxic gases
  • Rechargeable versions for all gas types
  • Non rechargeable for oxygen and toxic gases
  • Loud 95dBA audible alarm

Tetra - Personal multigas monitor
Tetra - Personal multigas monitor
  • Battery non- or rechargeable options
  • Graphic LCD for clear view
  • Single button operation
  • Loud 94dBA audible alarm
  • Shock and vibration resistant, IP 65

TXgard+ - Toxic and oxygen gas detector
TXgard+ - Toxic and oxygen gas detector
  • Calibration can be performed locally without the need for hot work permits
  • Local display and magnetic key enable calibration without opening the junction box
  • 4...20mA signal is provided
  • Optional alarm and fault relays are available