TXgard+

Toxic and oxygen gas detector

Features
  • Calibration can be performed locally without the need for hot work permits
  • Local display and magnetic key enable calibration without opening the junction box
  • 4...20mA signal is provided
  • Optional alarm and fault relays are available
Description

TXgard-Plus is a flameproof toxic and oxygen gas detector suitable for use in zone 1 or 2 hazardous areas. It is designed to detect toxic gases and oxygen using a range of electrochemical sensors. 

A local display and magnetically operated switches allow non-intrusive one-man calibration without a hot work permit. 

Powered by 24 VDC (nominally) TXgard Plus provides a 4...20 mA signal (sink or source) proportional to the gas concentration and can also be fitted with optional alarm and fault relays. 


Technical data
Protection class IP65, IP66 with weatherproof cap
Cable entries 2 x M20 or 1/2”NPT
Power 10...30VDC, 100 mA max (relay version).
50 mA max. (non relay)
Operation temperatures -10 °C...+55 °C (14°F...131 °F)
Humidity 15...90% RH non-condensing
Relays (optional) SPNO or SPNC contacts rated 30Vdc 1A (non-inductive load)
Display 3-digit LCD back-lit display, LED status indicator

Similar Products


Flamgard - Flammable gas detector
Flamgard - Flammable gas detector
  • Calibration can be performed locally
  • Local display and magnetic key enable calibration
  • 4-20 mA
  • Optional alarm and fault relays are available

Xgard - Flammable, toxic or oxygen gas detector
Xgard - Flammable, toxic or oxygen gas detector
  • Aluminium, stainless steel or glass-reinforced nylon body
  • Operating range: -40...+80°C, 0-99% RH (non-condensing)
  • 2- wire 4-20mA or 3- wire mV bridge
  • IP54 to IP65
  • Deploy in hazardous environment certified

Xgard-IR - Infrared gas detector
Xgard-IR - Infrared gas detector
  • Fail safe IR sensor technology (Immune to poisoning)
  • Aluminium or stainless steel body
  • 3-wire 4-20 mA
  • Operating range: -20...+55 °C, 0-95% RH (non-condensing)
  • >5 years sensor life

Gasman - Personal single gas detector
Gasman - Personal single gas detector
  • Available for flammable gas, oxygen and toxic gases
  • Rechargeable versions for all gas types
  • Non rechargeable for oxygen and toxic gases
  • Loud 95dBA audible alarm

Tetra - Personal multigas monitor
Tetra - Personal multigas monitor
  • Battery non- or rechargeable options
  • Graphic LCD for clear view
  • Single button operation
  • Loud 94dBA audible alarm
  • Shock and vibration resistant, IP 65

E2608-VOC - Solvent Vapors Detector
E2608-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2610-VOC - Solvent Vapor Detector
E2610-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

Xsafe - Gas detector for non-hazardous areas
Xsafe - Gas detector for non-hazardous areas
  • Aluminium junction box
  • Working range: -40...+80°C, 0-99% RH
  • 3-wire 4-20 mA
  • IP65
  • Deploy in non-hazardous environment

E2611-VOC - Solvent Vapor Detector
E2611-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-VOC - Solvent Vapors Transmitter
E2618-VOC - Solvent Vapors Transmitter
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • 2 × 4-20 mA or 0-10 V, RS485

E2630-VOC - Solvent Vapor Detector
E2630-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

E2638-VOC - Solvent Vapors Detector
E2638-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-PID - Solvent Vapors Detector
E2608-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-PID - Solvent Vapors Transmitter
E2618-PID - Solvent Vapors Transmitter
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-PID - Solvent Vapors Detector
E2638-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-PID - Solvent Vapors Detector
E2648-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-VOC - Solvent Vapors Detector
E2648-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-PID - Flameproof Solvent Vapors Detector
E2670-PID - Flameproof Solvent Vapors Detector
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-VOC - Flameproof Solvent Vapors Detector
E2670-VOC - Flameproof Solvent Vapors Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485