Features
  • Available for flammable gas, oxygen and toxic gases
  • Rechargeable versions for all gas types
  • Non rechargeable for oxygen and toxic gases
  • Loud 95dBA audible alarm
Description

Gasman features simple, single-button control and has an easy-to-read, backlit LCD display to ensure clear viewing of gas level readings, alarm conditions and battery life.

Data and event logging are available as standard, and there is a built-in 30 day advance warning when calibration is due.


Technical data
Audible alarms 95dB
Battery Type rechargeable Li-ion battery for all gas types
non-rechargeable lithium battery for toxics and oxygen
Operating time rechargeable 12 hours minimum for flammable unit
non rechargeable up to 2 years
Operating temp range -20...+65°C
Humidity 20...90% RH
Protection class IP65
PC interface RS232

Similar Products


Flamgard - Flammable gas detector
Flamgard - Flammable gas detector
  • Calibration can be performed locally
  • Local display and magnetic key enable calibration
  • 4-20 mA
  • Optional alarm and fault relays are available

Xgard - Flammable, toxic or oxygen gas detector
Xgard - Flammable, toxic or oxygen gas detector
  • Aluminium, stainless steel or glass-reinforced nylon body
  • Operating range: -40...+80°C, 0-99% RH (non-condensing)
  • 2- wire 4-20mA or 3- wire mV bridge
  • IP54 to IP65
  • Deploy in hazardous environment certified

Xgard-IR - Infrared gas detector
Xgard-IR - Infrared gas detector
  • Fail safe IR sensor technology (Immune to poisoning)
  • Aluminium or stainless steel body
  • 3-wire 4-20 mA
  • Operating range: -20...+55 °C, 0-95% RH (non-condensing)
  • >5 years sensor life

Tetra - Personal multigas monitor
Tetra - Personal multigas monitor
  • Battery non- or rechargeable options
  • Graphic LCD for clear view
  • Single button operation
  • Loud 94dBA audible alarm
  • Shock and vibration resistant, IP 65

TXgard+ - Toxic and oxygen gas detector
TXgard+ - Toxic and oxygen gas detector
  • Calibration can be performed locally without the need for hot work permits
  • Local display and magnetic key enable calibration without opening the junction box
  • 4...20mA signal is provided
  • Optional alarm and fault relays are available

E2608-VOC - Solvent Vapors Detector
E2608-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2610-VOC - Solvent Vapor Detector
E2610-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

Xsafe - Gas detector for non-hazardous areas
Xsafe - Gas detector for non-hazardous areas
  • Aluminium junction box
  • Working range: -40...+80°C, 0-99% RH
  • 3-wire 4-20 mA
  • IP65
  • Deploy in non-hazardous environment

E2611-VOC - Solvent Vapor Detector
E2611-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-VOC - Solvent Vapors Transmitter
E2618-VOC - Solvent Vapors Transmitter
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • 2 × 4-20 mA or 0-10 V, RS485

E2630-VOC - Solvent Vapor Detector
E2630-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

E2638-VOC - Solvent Vapors Detector
E2638-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-PID - Solvent Vapors Detector
E2608-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-PID - Solvent Vapors Transmitter
E2618-PID - Solvent Vapors Transmitter
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-PID - Solvent Vapors Detector
E2638-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-PID - Solvent Vapors Detector
E2648-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-VOC - Solvent Vapors Detector
E2648-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-PID - Flameproof Solvent Vapors Detector
E2670-PID - Flameproof Solvent Vapors Detector
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-VOC - Flameproof Solvent Vapors Detector
E2670-VOC - Flameproof Solvent Vapors Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm