E2670-VOC

Flameproof Solvent Vapors Detector

Features
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485
Description

E2670 series is a new line of flameproof detectors-transmitters intended for use in ATEX Zones 2 and 22.

E2670 series devices are based on PluraSens® multifunctional platform.

Solvent vapors transmitter E2670-VOC is intended to detect ethanol, toluene, xylene and other VOCs.

The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime.

According to user's preferences the detector can be ordered for either fire prevention (range 0...100% LEL) or for toxicity prevention (range 0...1000 ppm).

Two relays with closing contact (optional) may be used for remote signalling or concentration control. Two alarm set-points are user settable.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical data
Detected vapors acetone, ethanol, toluene, xylene etc
Default calibration toluene
Sensor type metal-oxide semiconductor
Sampling method diffusion
Detection range 0...100% LEL (flammable range)
0...1000 ppm (toxic range)
Resolution 0,1% LEL for LEL range
1 ppm for ppm range
Sensor lifetime > 5 years
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays (option) 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Default alarm set-points 20% LEL / 50% LEL
100 ppm / 300 ppm
Enclosure die-cast aluminium, wall mount, IP65
Dimensions H155 × W145 × D110 mm
Operating conditions -40...+70 °C, < 95 %RH
safe areas and ATEX Zones 2 and 22

Similar Products


Xgard - Flammable, toxic or oxygen gas detector
Xgard - Flammable, toxic or oxygen gas detector
  • Aluminium, stainless steel or glass-reinforced nylon body
  • Operating range: -40...+80°C, 0-99% RH (non-condensing)
  • 2- wire 4-20mA or 3- wire mV bridge
  • IP54 to IP65
  • Deploy in hazardous environment certified

Xgard-IR - Infrared gas detector
Xgard-IR - Infrared gas detector
  • Fail safe IR sensor technology (Immune to poisoning)
  • Aluminium or stainless steel body
  • 3-wire 4-20 mA
  • Operating range: -20...+55 °C, 0-95% RH (non-condensing)
  • >5 years sensor life

Gasman - Personal single gas detector
Gasman - Personal single gas detector
  • Available for flammable gas, oxygen and toxic gases
  • Rechargeable versions for all gas types
  • Non rechargeable for oxygen and toxic gases
  • Loud 95dBA audible alarm

Tetra - Personal multigas monitor
Tetra - Personal multigas monitor
  • Battery non- or rechargeable options
  • Graphic LCD for clear view
  • Single button operation
  • Loud 94dBA audible alarm
  • Shock and vibration resistant, IP 65

TXgard+ - Toxic and oxygen gas detector
TXgard+ - Toxic and oxygen gas detector
  • Calibration can be performed locally without the need for hot work permits
  • Local display and magnetic key enable calibration without opening the junction box
  • 4...20mA signal is provided
  • Optional alarm and fault relays are available

E2608-VOC - Solvent Vapors Detector
E2608-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2610-VOC - Solvent Vapor Detector
E2610-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

Xsafe - Gas detector for non-hazardous areas
Xsafe - Gas detector for non-hazardous areas
  • Aluminium junction box
  • Working range: -40...+80°C, 0-99% RH
  • 3-wire 4-20 mA
  • IP65
  • Deploy in non-hazardous environment

E2611-VOC - Solvent Vapor Detector
E2611-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-VOC - Solvent Vapors Transmitter
E2618-VOC - Solvent Vapors Transmitter
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • 2 × 4-20 mA or 0-10 V, RS485

E2630-VOC - Solvent Vapor Detector
E2630-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

E2638-VOC - Solvent Vapors Detector
E2638-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-PID - Solvent Vapors Detector
E2608-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-PID - Solvent Vapors Transmitter
E2618-PID - Solvent Vapors Transmitter
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-PID - Solvent Vapors Detector
E2638-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-PID - Solvent Vapors Detector
E2648-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-VOC - Solvent Vapors Detector
E2648-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-PID - Flameproof Solvent Vapors Detector
E2670-PID - Flameproof Solvent Vapors Detector
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485