Features Aluminium junction box Working range: -40...+80°C, 0-99% RH 3-wire 4-20 mA IP65 Deploy in non-hazardous environment Description - Add To Inquiry Documents TechnicalDatasheet UserManual
Flamgard - Flammable gas detector Calibration can be performed locally Local display and magnetic key enable calibration 4-20 mA Optional alarm and fault relays are available
Xgard - Flammable, toxic or oxygen gas detector Aluminium, stainless steel or glass-reinforced nylon body Operating range: -40...+80°C, 0-99% RH (non-condensing) 2- wire 4-20mA or 3- wire mV bridge IP54 to IP65 Deploy in hazardous environment certified
Xgard-IR - Infrared gas detector Fail safe IR sensor technology (Immune to poisoning) Aluminium or stainless steel body 3-wire 4-20 mA Operating range: -20...+55 °C, 0-95% RH (non-condensing) >5 years sensor life
Gasman - Personal single gas detector Available for flammable gas, oxygen and toxic gases Rechargeable versions for all gas types Non rechargeable for oxygen and toxic gases Loud 95dBA audible alarm
Tetra - Personal multigas monitor Battery non- or rechargeable options Graphic LCD for clear view Single button operation Loud 94dBA audible alarm Shock and vibration resistant, IP 65
TXgard+ - Toxic and oxygen gas detector Calibration can be performed locally without the need for hot work permits Local display and magnetic key enable calibration without opening the junction box 4...20mA signal is provided Optional alarm and fault relays are available
E2608-VOC - Solvent Vapors Detector Stable long-life metal-oxide sensor Range 0...100% LEL or 0...1000 ppm Resolution 0,1% LEL or 1 ppm Two SPST relays 2 × 4-20 mA or 0-10 V, RS485
E2610-VOC - Solvent Vapor Detector Stable long-life metal-oxide sensor Range 0...100% LEL or 0...500 ppm Resolution 0,1% LEL or 1 ppm Two SPDT relays UART digital interface
E2611-VOC - Solvent Vapor Detector Stable long-life metal-oxide sensor Range 0...100% LEL or 0...1000 ppm Resolution 0,1% LEL or 1 ppm Two SPST relays 2 × 4-20 mA or 0-10 V, RS485
E2618-VOC - Solvent Vapors Transmitter Stable long-life metal-oxide sensor Range 0...100% LEL or 0...1000 ppm Resolution 0,1% LEL or 1 ppm 2 × 4-20 mA or 0-10 V, RS485
E2630-VOC - Solvent Vapor Detector Stable long-life metal-oxide sensor Range 0...100% LEL or 0...500 ppm Resolution 0,1% LEL or 1 ppm Two SPDT relays UART digital interface
E2638-VOC - Solvent Vapors Detector Stable long-life metal-oxide sensor Range 0...100% LEL or 0...1000 ppm Resolution 0,1% LEL or 1 ppm Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2608-PID - Solvent Vapors Detector Highly sensitive Photo Ionization Detector Range 0...40 or 0...200 ppm isobutylene Resolution 0,01 ppm or 1 ppm isobutylene Two SPST relays 2 × 4-20 mA or 0-10 V, RS485
E2618-PID - Solvent Vapors Transmitter Highly sensitive Photo Ionization Detector Range 0...40 or 0...200 ppm isobutylene Resolution 0,01 ppm or 1 ppm isobutylene 2 × 4-20 mA or 0-10 V, RS485
E2638-PID - Solvent Vapors Detector Highly sensitive Photo Ionization Detector Range 0...40 or 0...200 ppm isobutylene Resolution 0,01 ppm or 1 ppm isobutylene Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2648-PID - Solvent Vapors Detector Highly sensitive Photo Ionization Detector Range 0...40 or 0...200 ppm isobutylene Resolution 0,01 ppm or 1 ppm isobutylene Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2648-VOC - Solvent Vapors Detector Stable long-life metal-oxide sensor Range 0...100% LEL or 0...1000 ppm Resolution 0,1% LEL or 1 ppm Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2670-PID - Flameproof Solvent Vapors Detector Suitable for ATEX Zones 2 and 22 Highly sensitive Photo Ionization Detector Range 0...40 or 0...200 ppm isobutylene Resolution 0,01 ppm or 1 ppm isobutylene Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485
E2670-VOC - Flameproof Solvent Vapors Detector Suitable for ATEX Zones 2 and 22 Stable long-life metal-oxide sensor Range 0...100% LEL or 0...1000 ppm Resolution 0,1% LEL or 1 ppm Two SPST relays option 2 × 4-20 mA or 0-10 V, RS485